JET POWER

With JET POWER, HITZINGER presents a new brand of ground power supply for aircraft in the flight preparation phase. Enhanced efficiency and the reduction in total cost of ownership (TCO) combined with improved environmental- and user-friendliness make the JET POWER one of the most innovative ground power units able to meet increased requirements in the long term.

The JET POWER is the little sister to the D POWER. Development of the JET POWER not only focused on achieving the lowest consumption and sound level, it centred on achieving remarkable compactness. This is reflected in the appealing design and ergonomically arranged control panels.

Technical data

Versions

  • Towed version

Power classes

  • JET POWER 30 to 60 kVA

Diesel engines

  • Deutz
  • Cummins

Technical data

  • Voltage: 200/115 VAC
  • Frequency: 400 Hz

Environment

  • Ambient temperature: -30 °C to +52 °C
  • Relative humidity: up to 95 %
  • Noise level: <68 dB (A) @ 7 m

Options

  • 28 VDC unit for single or simultaneous operation, continuous load: 600 A, maximum load: 2,500 A
  • 2x28 / 56 VDC for simultaneous operation
  • Modified protection by isolation (IT) in accordance with DFS 400
  • Integration of telematics systems
  • Tailored versions on request

Technical highlights

The JET POWER is characterised by optimised economy, increased efficiency and the lowest noise emissions. Low maintenance and extremely easy servicing and operation complete the profile of this purpose-made development. We guarantee you optimum power performance.

Optimised economy
With the engine speed lowered to 2,000 rpm and when used in conjunction with an extremely efficient 400 Hz alternator, the JET POWER generation manages to achieve greater economy, particularly as a result of reduced fuel consumption. This in turn leads to lower maintenance costs with extremely low noise emissions.

Increased efficiency
Thanks to the high efficiency of the alternator, independent of the load curve, aircraft can be supplied as economically as possible even under partial load.

Maximum serviceability
The modular arrangement of the switchgear simplifies all service work. A large-size soundproofing enclosure provides optimum access for servicing and maintenance.

Simplified user operation
The touchpanel of the control station offers intuitive user navigation. Easy to read even in strong sunlight, it is also dust- and water-tight and suitable for use in the most adverse airfield conditions. The resistive touchscreen is straightforward to use even when gloves are worn. For the rare occasion that the JET POWER is out of use, a protective flap gives the touchscreen display optimum shelter against wind and weather.

Standards

  • ISO 6858 Aircraft ground support electrical supplies
  • BS 2G 219 General requirements for ground support equipment
  • SAE ARP 5015 Ground Equipment 400Hz ground power performance requirements
  • DFS 400 Specification for 400Hz aircraft power
  • MIL-STD-704 Aircraft electrical power characteristics
  • EN2282 Characteristics of aircraft electrical supplies
  • EN61439 Low-voltage switchgear and controlgear assemblies
  • EN61000-6-4 Electromagnetic compatibility
  • EN12312-20 Specific requirements for electrical ground power units
  • EN1915 -1 / -2 Aircraft ground support equipment, General safety requirements